Industrial Oil Burner BNL5
Home / PRODUCTS / One Stage Light Oil Burner / Industrial Oil Burner BNL5
Industrial Oil Burner BNL5
Industrial Oil Burner BNL5

Industrial Oil Burner BNL5


The BNL5 burner uses diesel fuel and is classified as a small to medium power oil burner, primarily suitable for industrial and commercial heating and certain specialized processes.


🔘Fuel:diesel oil

🔘Heating Power:24-66kw

🔘Oil Flow:2-5.5kg/h




  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction

Question 1-Product Description


SHORT DESCRIPTION

  1. Fuel Adaptability

    • Runs on diesel oil, which is clean, easy to store, and suitable for locations without natural gas pipelines or requiring mobile heat supply.

    • Simple fuel system with no complex pretreatment (compared to heavy oil).

  2. Moderate Power Range

    • Power output range: 24-66 kW, suitable for small to medium-scale heating demands.

    • Fuel modulation ratio ≈ 1:2.75 (2-5.5 kg/h), allowing adaptation to partial load changes.

  3. Simple and Reliable Control

    • Single-stage (on/off) fire control: Simple structure, low failure rate, easy maintenance.

    • Suitable for continuous heating applications where precise temperature control (±5°C) is not critical.

  4. Low Pressure Requirement

    • Combustion chamber pressure only 2.5 mbar, compatible with most conventional boiler designs due to low back-pressure demand.

  5. Universal Power Supply

    • Operates on 220V/50Hz single-phase AC, eliminating the need for three-phase industrial power and enabling flexible installation.


PRODUCT VIDEO


Question 2-Product Parameter


BNL5 PARAMETERS

ModelBNL5
FuelDiesel Oil
Power(kw)24-66
Oil Flow(kg/h)2-5.5
Power Supply1N AC 50Hz 220V
Motor Power(kw)/
Combustion Chamber Pressure(mbar)2.5
ControlOne stage fire
Packing Size(mm)
500x440x390
Weight(kg)12(Wooden case packing)

*For more parameters, please contact: info@bntet.com


Question 3-Product Display


light-oil-burner-bnl5-4

PRODUCT DETAILS

1.Flame stabilising plate
2.Combustion tube
3.Flame detector
4.Oil Pipe
5.Oil Pump
6.Fan


light-oil-burner-bnl5-details01

light-oil-burner-bnl5-details01

light-oil-burner-bnl5-details02

light-oil-burner-bnl5-details02


Question 4-Application


Hot Air Generators

Used in drying ovenspaint spray boothsgrain/agricultural product drying equipmentelectroplating tank heating, etc., to supply clean, dry hot air.

Industrial Boilers

Provides heat for small to medium-sized hot water boilerssteam boilers, or thermal oil boilers, used for factory heating, process heating, or domestic hot water supply. 

Melting and Holding

Used in melting furnaces and holding furnaces for low-melting-point metals such as aluminum and zinc.

Asphalt Heating and Maintenance

Used for heating and circulation maintenance in asphalt tanks and asphalt mixing plants.


Question 5-FAQ


Q1: What type of boiler is this burner suitable for?
A: The BNL5 is suitable for small steam boilers, hot water boilers, or hot air boilers with a thermal power requirement between 24-66 kW. For specific selection, ensure the boiler's design back pressure does not exceed the burner's allowable limit of 2.5 mbar and verify compatibility with the boiler's connection dimensions. It is recommended to consult the equipment supplier for final confirmation.

Q2: What is its noise level?
A: Diesel burners generate noise from the fan and combustion during operation. The BNL5, being a small-to-medium power model, has a controllable noise level. If installed in noise-sensitive areas (e.g., near residential areas, indoors), noise reduction measures are recommended, such as installing an acoustic enclosure for the burner or using silenced air intake ducts.

Q3: What does "One stage fire" control mean? What are its advantages and disadvantages?
A: "One stage fire" means the burner operates in only two states: fully on and completely off, with no ability to modulate the flame.

  • Advantages: Simple structure, low cost, low failure rate, easy maintenance.

  • Disadvantages: Causes relatively significant fluctuations in boiler temperature or pressure (frequent cycling on and off) around the setpoint, resulting in relatively lower thermal efficiency. It is unsuitable for processes requiring extremely precise temperature control.

  • Comparison: For smoother temperature control and energy savings, consider "two-stage" or "proportional modulation" burners.


Question 6-Our service


Spare Parts Supply

Establish an efficient genuine spare parts supply chain to ensure rapid delivery of core components like nozzles, electrodes, fuel pumps, programmers, and fans.

Simulation & Testing Support

Demonstrates the burner's performance under actual operating conditions (flame pattern, emission data, etc.).

Selection & Solution Design

Provide accurate burner selection recommendations based on the customer's boiler/equipment model, thermal power requirements, fuel type, and control needs

Professional Installation Guidance

Provide detailed installation manuals and video tutorials.Offer remote installation guidance via phone or video call.



Hot Tags: Industrial Oil Burner,oil burner,industrial burner,diesel oil burner,diesel burner

You Might Also Like
Send